Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822

Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.
The YR05820 // YR05822 Laboratory Fume Hood is engineered for optimal safety and efficiency in environments where the handling of aggressive chemicals is routine. Constructed with a robust stainless steel body coated in epoxy resin powder, this fume cupboard stands resilient against strong acids and alkalis, ensuring durability and reliability in both laboratory and hospital settings. The adjustable 5 mm thick tempered glass front window offers protection from toxic fumes, while the 12.7 mm phenolic resin work surface is chemical-resistant, promising long-term use. The ventilation system includes an adjustable axial flow blower, maintaining a noise level below 60 dB for a quiet and controlled environment.
Market Price
The market price for the YR05820 // YR05822 Laboratory Fume Hood ranges between $3100 and $3800, reflecting its high-quality materials including stainless steel and phenolic resin, alongside advanced technological features. This product is a strategic investment for laboratories and hospitals aiming to uphold superior safety and operational standards.
Frequently Asked Questions
- Is the YR05820 // YR05822 fume hood user-friendly?
Yes, the fume hood is designed for simplicity, featuring a manual front window and an intuitive control panel for blower speed and window height adjustments. - What kind of protection does it offer?
This fume hood safeguards operators from hazardous chemical fumes, promoting a safe working atmosphere through its adjustable ventilation and corrosion-resistant materials. - How noisy is it during operation?
The noise level is below 60 dB, ensuring a peaceful working environment conducive to concentration.
Advantages and Disadvantages
The YR05820 // YR05822 Fume Hood boasts primary advantages such as its sturdy stainless steel composition and a chemically resistant working surface. Its adjustable ventilation and low noise output further enhance comfort and safety. However, its price point may pose a challenge for laboratories with constrained budgets, especially compared to other options in the market.
Field Use
This fume hood is suited for chemical laboratories and hospitals engaging with hazardous substances. Its capability to resist acids and alkalis allows for intensive, prolonged usage where exposure to corrosive agents is frequent. The effective ventilation system eradicates fumes efficiently, ensuring the safety of both the user and the environment.
Recommendations
Regular maintenance is key to preserving the YR05820 // YR05822 Fume Hood in optimal condition. This includes periodic cleaning of the ventilation ducts and checks on the blower and window controls. Utilizing it within the recommended airflow parameters will extend its longevity and performance, ensuring your investment yields maximum returns.
Features
- Stainless steel construction with epoxy resin coating
- 5 mm tempered glass adjustable front window
- Phenolic resin work surface with chemical resistance
- Built-in adjustable axial flow blower
- Noise level under 60 dB, offering a quiet work environment
- Includes LED lamp and waterproof sockets
- Optional outer centrifugal blower
Technical Specifications
| Model | YR05820 | YR05821 | YR05822 | |
| External Size (W*D*H) (mm) | 1200*800*1500 | 1500*800*1500 | 1800*800*1500 | |
| Internal Size (W*D*H) (mm) | 950*700*1150 | 1250*700*1150 | 1550*700*1150 | |
| Work Surface Height | 800mm | |||
| Max Opening of window | 750mm | |||
| Air Velocity/Exhaust air volume | 0.4-0.6m/s,800-1000m³/h | |||
| Noise | ≤60dB | |||
| LED Lamp | 10W*1 | |||
| Blower | Built-in axial flow blower;Speed adjustable. | |||
| Front Window | Manual,5mm toughened glass,height adjustable. | |||
| Power Supply | AC220V±10%,50/60Hz; | |||
| Consumption | 100W | |||
| Material | Main Body | 1.2mm thickness stainless steel with epoxy resin powder coating. | ||
| Inner Side | 5mm thickness compact,resistant to strong acid and alkali. | |||
| Work Table | Chemical resistant phenolic resin, thickness 12.7mm. | |||
| Standard Accessory | LED lamp,Built-in axial flow blower with speed adjustable. | |||
| Waterproof socket*3 | ||||
| 3 meter PP duct,Diameter:250mm | ||||
| Optional Accessory | Outer centrifugal blower(300W),resistant to strong acid,alkali. | |||
| Gross Weight (kg) | 235 | 265 | 300 | |
Technische Daten
| Hersteller | Kalstein |
|---|
Verfügbare Modelle
- Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 - YR05820 (SKU: YR05820)
- Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 - YR05821 (SKU: YR05820)
- Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 - YR05822 (SKU: YR05820)
Bildergalerie

Video Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822
Häufige Fragen
Wie erfahre ich die Preise für Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822?
Um den Preis für Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 zu erfahren, senden Sie uns bitte eine E-Mail über das Kontaktformular AQUI.
Wie sind die Lieferzeiten für Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822?
Die Lieferzeit hängt von der Lagerverfügbarkeit und der Versandart (Luft oder See) ab. Auf Lager: Luft 15-30 Tage, See 45-60 Tage. Nicht auf Lager: Luft 30-60 Tage, See 60-90 Tage.
Wie kann ich Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 kaufen?
Sie können per E-Mail ([email protected]), Telefon (+33 (0) 1 70 39 26 50) oder über die offizielle Kalstein-Website Ihres Landes bestellen.
Wie funktioniert die Garantie für Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822?
Alle Kalstein-Geräte haben eine 1-jährige Garantie gegen Herstellungsfehler. Schäden durch unsachgemäße Installation oder Bedienung sind ausgeschlossen. Siehe unsere «Allgemeinen Geschäftsbedingungen» AQUI.
Kann ich online ein Angebot für Laboratory Fume Hood,acid and alkali resistance Fume Cupboard Hospital Laboratory equipment YR05820 // YR05822 anfordern?
Ja, Sie können direkt auf unserer offiziellen Website ein Angebot anfordern. Klicken Sie AQUI.