Automatic Nucleic Acid Extractor YR01869-2

FabricanteKalstein

Description

The Automatic Nucleic Acid Extractor YR01869-2 is a groundbreaking device engineered to enhance the nucleic acid extraction process. Utilizing advanced rotary mixing technology (RMT), this extractor offers unparalleled performance with the ability to handle 16 x n different yields simultaneously, making it ideal for laboratories that require high throughput without compromising accuracy. Its intuitive 6.86-inch touch screen and remote control capabilities via smartphone or tablet ensure a seamless user experience, while its compact design ensures it’s the perfect fit for any lab. Recognized with the prestigious Red Dot Design Award 2021, it’s an investment in efficiency and precision.

Market Price

The market price of the Automatic Nucleic Acid Extractor YR01869-2 generally falls within the range of $8800 to $9500 USD. This investment in efficiency and innovation is well worth it for laboratories and research facilities looking to enhance their nucleic acid extraction capabilities. For a personalized quote and to access special offers, potential buyers are encouraged to use the Kalstein Plus platform, which provides tailored pricing and additional benefits like specialized technical support.

Frequently Asked Questions

  • What types of samples can be processed with the YR01869-2? The device is versatile, supporting a variety of samples and is particularly suited for precise DNA and RNA extractions.
  • How user-friendly is the device? The YR01869-2 is designed for ease of use with an intuitive touch screen and remote control features via mobile devices, ensuring efficient operation.
  • What maintenance is required for optimal performance? Regular cleaning and system updates are crucial, alongside following the manufacturer’s maintenance guidelines to ensure longevity and reliability.

Advantages and Disadvantages

  • High Flexibility: Capable of managing multiple projects with 16 x n yields simultaneously.
  • Automated Workflow: Features such as automatic reagent identification increase efficiency and reduce manual workload.
  • Advanced Protection System: UV lamps, internal negative pressure, and HEPA filtration minimize contamination risks.
  • Compact and Portable Design: Easy to move and use in various locations, making it perfect for dynamic laboratory environments.

Disadvantages:

  • High Price: While cost-effective for larger labs, it may be less accessible for small laboratories with limited budgets.
  • Requires Specialized Maintenance: Trained personnel are necessary for maintenance and system updates due to the device’s advanced nature.

Product Use in the Field

The Automatic Nucleic Acid Extractor YR01869-2 is primarily utilized in genetic research laboratories, clinical diagnostic centers, and biotechnology fields. Its mobile power source and portable design make it essential in hospitals, forensic labs, and scientific research facilities. The instrument excels in nucleic acid extraction, biological sample analysis, and PCR projects, offering flexibility and speed where immediate results are crucial.

Recommendations

To maximize the YR01869-2‘s performance, adherence to the manufacturer’s maintenance instructions is crucial. This includes regular cleaning and protocol updates. Leveraging its ability to conduct simultaneous assays can significantly boost lab productivity. Furthermore, utilizing the UV disinfection system and HEPA filtration is essential to prevent cross-contamination and ensure the accuracy of results.

Technical Specifications

Model YR01869-2
Throughput 16
Processing Volume 20-1700μL
Sample Processing Volume 200-500μL
Compatible Consumables Customized 96-deep-well plates, single 6-strip tubes
Inter-well Difference CV≤3%
Mixing Method Rotary mixing
Rotary Speed 100~3000rpm
Temperature Control Range Temperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control Accuracy Heating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
Languages Chinese/English
Protocol Management Flexible to create, edit and delete protocols
Operation Mode Mode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic Control Automatic opening and closing of the experiment cabin
Reagent Identification Automatic identification of reagent information and running the assays
Mixing Sleeve Monitoring Real-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue ≤1%
Power Failure Protection Choose freely whether or not to continue the experiment when the power is on again after cutting off
Disinfection Ozone + UV disinfection
Auto Power-off Auto power-off after UV disinfection
Negative-Pressure Filtration Negative pressure HEPA filtration module
Connection Port Type USB port
Weight 7.4Kg (net)
Instrument Dimensions 210mm(L)*229mm(W)*242mm(H)
Power Supply AC220V, 50Hz

Additional information

Weight 11 kg
Dimensions 34 × 29 × 31 cm

Quote List

Quote List

No products in the list

Product categories

In this section you can select the sector or product of your interest.

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.