The Orbital-Shaker YR05766 combines technical features for laboratory routines, operational continuity and a coherent equipment selection process.
This page provides an overview of the Orbital-Shaker YR05766, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in Germany, with selection criteria adapted to local purchasing, installation and support conditions.
Wichtige Faktoren

Before selecting the Orbital-Shaker YR05766, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
Its use is oriented to laboratory routines that require observation, control and operational continuity.
For the market in Germany, evaluation should consider local context such as industrial labs, Mittelstand pharma, strict DIN/EN standards and match the product to the real workload of the Labor.
Marktpreisspanne

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In Germany, budget comparison should include local regulatory requirements, 230V/50Hz power conditions, accessories, logistics and after-sales support.
Preis-Leistungs-Verhältnis

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Vor- und Nachteile

Its use is oriented to laboratory routines that require observation, control and operational continuity.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Erwartete Lebensdauer je nach Nutzung und Wartung

Modell YR05766 (aktuell) YR05767 YR05768 Modus der Rüttelung orbital/ konvolution schwenken wavina / dreidimensional Steuerung PID Mikrocomputersteuerung Monitor Digitale LED-Anzeige Amplitude Ø30 25 mm 3-15°(manuell) Frequenz (rpm/min) 15-240 15-90 Empfindlichkeit (rpm) ±2 Timer 0-99 Stunden 59 Minuten Größe der Plattform (mm) 320×265 Plattenanzahl 1 Gesamtgröße (mm) 330x480x160 330x480x220 330x480x180 Energie 30W Stromversorgung AC 90-260V, 50-60HZ Umgebungstemperatur -10 °C-65 °C
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to Germany helps preserve service continuity and plan preventive maintenance without extended downtime.
Spezifikationstabelle des Orbital-Shaker YR05766

Orbital-Shaker YR05766
- Durch die Verwendung von uniaxialer Übertragungstechnologie arbeitet die Maschine reibungslos und geräuscharm;
- Bürstenloser Gleichstrommotor, lange Lebensdauer, wartungsfrei;
- Überstromschutzfunktion, schaltet die Energie automatisch ab, ohne andere Geräte zu beeinträchtigen;
- Automatische Speicherfunktion, nach dem Einschalten läuft sie gemäß der letzten Einstellung;
- Langsame Startfunktion, um Spritzer von Flüssigkeiten zu vermeiden.
Technische Spezifikationen
| Modell | YR05766 (aktuell) | YR05767 | YR05768 |
| Modus der Rüttelung | orbital/ konvolution | schwenken | wavina / dreidimensional |
| Steuerung | PID Mikrocomputersteuerung | ||
| Monitor | Digitale LED-Anzeige | ||
| Amplitude | Ø30 | 25 mm | 3-15°(manuell) |
| Frequenz (rpm/min) | 15-240 | 15-90 | |
| Empfindlichkeit (rpm) | ±2 | ||
| Timer | 0-99 Stunden 59 Minuten | ||
| Größe der Plattform (mm) | 320×265 | ||
| Plattenanzahl | 1 | ||
| Gesamtgröße (mm) | 330x480x160 | 330x480x220 | 330x480x180 |
| Energie | 30W | ||
| Stromversorgung | AC 90-260V, 50-60HZ | ||
| Umgebungstemperatur | -10 °C-65 °C | ||
Häufig gestellte Fragen zu Orbital-Shaker YR05766
How do I choose the right orbital-shaker yr05766 for my Labor?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.