Kalstein

Vertical Electric Heating Laboratory YR05199

Vertical Electric Heating Laboratory YR05199

The Vertical Electric Heating Laboratory Freeze Dryer YR05199 combines technical features for laboratory routines, operational continuity and a coherent equipment selection process.

This page provides an overview of the Vertical Electric Heating Laboratory Freeze Dryer YR05199, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.

This Kalstein model is available for laboratories in Germany, with selection criteria adapted to local purchasing, installation and support conditions.

Ver más

Key factors to consider

Key factors to consider

Before selecting the Vertical Electric Heating Laboratory Freeze Dryer YR05199, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

Its use is oriented to laboratory routines that require observation, control and operational continuity.

For the market in Germany, evaluation should consider local context such as industrial labs, Mittelstand pharma, strict DIN/EN standards and match the product to the real workload of the laboratory.

Market price range

Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In Germany, budget comparison should include local regulatory requirements, 230V/50Hz power conditions, accessories, logistics and after-sales support.

Value for money

Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Advantages and disadvantages

Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Expected lifespan based on use and maintenance

Expected lifespan based on use and maintenance

Model YR05198 YR05199 (current) YR05200 YR05201 Lyophilized area 0.18m²/0.27m² 0.09m² 0.18m²/0.27m² 0.09m² Panel material (material thickness 10 mm) 1.8L/2.7L 0.9L 1.8L/2.7L 0.9L Material tray Ф240mm 4/6 layers Ф200mm 3 layers Ф240mm 4/6 layers Ф200mm 3 layers Distance between material plates 70 mm/50 mm 70 mm 70 mm/50 mm 70 mm Storage temperature -40 ~ +60°C Cold trap temperature ≤ 60 ° C (no load), optional ≤ -80 ° C (no load) Water uptake capacity 6 kg/24h Ultimate vacuum ≤ 5pa (no load) Power 1800w Host weight 105 KG Central unit dimensions 630×580×1455mm 630×580×1455mm 630×580×1455mm 630×580×1455mm

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to Germany helps preserve service continuity and plan preventive maintenance without extended downtime.

Specifications table for the Vertical Electric Heating Laboratory YR05199

Vertical Electric Heating Laboratory YR05199

Vertical Electric Heating Laboratory YR05199

El liofilizador al vacío de laboratorio se utiliza ampliamente en medicina, farmacia, investigación biológica, química y alimentación. Los artículos liofilizados son fáciles de almacenar durante mucho tiempo, y se pueden restaurar al estado anterior a la liofilización y mantener las características bioquímicas originales después de añadir agua. El liofilizador es adecuado para uso en laboratorio y cumple los requisitos de la liofilización rutinaria en la mayoría de los laboratorios.
Características


  • Fijación del proceso de liofilización

  • Control de la velocidad de calentamiento con calefacción eléctrica de estante

  • Pantalla táctil de 7 pulgadas

  • Trampa fría y mesa de operaciones de acero inoxidable

  • Un sifón de gran apertura con función de precongelación

  • Trampa de frío Desescarche eléctrico

  • Conmutación flexible de las unidades de vacío (Pa, mBar, etc.)

  • Función de protección de la bomba de vacío con el ajuste de la bomba de vacío para iniciar la temperatura de la trampa de frío.


Especificaciones técnicas

ModelYR05198YR05199
(current)
YR05200YR05201
Lyophilized area0.18m²/0.27m²0.09m²0.18m²/0.27m²0.09m²
Panel material (material thickness 10 mm)1.8L/2.7L0.9L1.8L/2.7L0.9L
Material trayФ240mm 4/6 layersФ200mm 3 layersФ240mm 4/6 layersФ200mm 3 layers
Distance between material plates70 mm/50 mm70 mm70 mm/50 mm70 mm
Storage temperature-40 ~ +60°C
Cold trap temperature≤ 60 ° C (no load), optional ≤ -80 ° C (no load)
Water uptake capacity6 kg/24h
Ultimate vacuum≤ 5pa (no load)
Power1800w
Host weight105 KG
Central unit dimensions630×580×1455mm630×580×1455mm630×580×1455mm630×580×1455mm
View product

Frequently Asked Questions about the Vertical Electric Heating Laboratory YR05199

How do I choose the right Vertical Electric Heating Laboratory YR05199 for my laboratory?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?

Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.

Contact Us

Contact Kalstein