Key factors to consider

Key factors to consider

Before selecting the Spectrocolorimeter YR05516, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.

Its use is oriented to laboratory routines that require observation, control and operational continuity.

For the market in Germany, evaluation should consider local context such as industrial labs, Mittelstand pharma, strict DIN/EN standards and match the product to the real workload of the laboratory.

Market price range

Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.

The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.

In Germany, budget comparison should include local regulatory requirements, 230V/50Hz power conditions, accessories, logistics and after-sales support.

Value for money

Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.

Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.

Advantages and disadvantages

Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.

Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.

Expected lifespan based on use and maintenance

Expected lifespan based on use and maintenance

Model YR05516 (current) YR05517 optical geometry D/8 (diffuse illumination, D/8 (diffuse illumination, 8-degree viewing angle) 8-degree viewing angle) SCI/SCE Mode SCI/SCE Mode Complies with CIE No.15, GB/T Complies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 3978 GB 2893 GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 Feature double apertures, more adaptability; Used for precise single apertures, more adaptability; Used for precise color measurement and quality control in plastic electronics, paint and ink, printing and dyeing of textiles and garments, printing, ceramics, and other industries.

Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.

Support and spare-parts availability oriented to Germany helps preserve service continuity and plan preventive maintenance without extended downtime.

Specifications table for the Spectrocolorimeter YR05516

Spectrocolorimeter YR05516

Spectrocolorimeter YR05516

YR05516 // YR05519 es Kalstein que utiliza investigación y desarrollo de tecnología de núcleo autónomo de un instrumento de diferencia de color de luz portátil, es el instrumento de diferencia de color de arquitectura espectral de alto nivel, además de garantizar un Δ E relativo preciso al mismo tiempo, también para garantizar la precisión del valor absoluto de L, A y B durante mucho tiempo, en cualquier momento y en cualquier lugar puede pasar los estándares internacionales y los estándares nacionales de medición. Usando los sensores de matriz de fotodiodos de silicio incorporados (doble fila 24), importe la pizarra, Δ E * ab repetitivo controle fácilmente dentro de 0.1, tanto la velocidad de medición como la conveniencia de operación, sin necesidad de conectar la computadora o el software puede juzgar rápidamente la diferencia de color Medida, 8 mm de diámetro cumplen con la electrónica de plástico, pintura y tinta, impresión y teñido de textiles, impresión,
Características del producto


  • Φ Medición de 8 mm de diámetro, ángulo de 10 °, el observador puede cumplir con la mayoría de los requisitos de los clientes de la industria;

  • Combinación de fuente de luz LED de espectro completo, rejilla plana y pantalla táctil capacitiva de color verdadero, con un punto de partida alto;

  • Matriz de fotodiodos de silicio (24 grupos en columnas dobles), precisión de visualización 0,1, buena repetibilidad;

  • La vida útil de la fuente de luz es de más de 3 millones de mediciones en 5 años, y la batería de litio toma 6000 mediciones en 8 horas, que se puede recargar repetidamente y tiene una batería de larga duración;

  • Búsqueda, análisis y comparación de datos rápidos con 500 muestras de almacenamiento de datos y 10,000 muestras.


Especificaciones Técnicas

ModelYR05516
(current)
YR05517
optical geometryD/8 (diffuse illumination,D/8 (diffuse illumination,
8-degree viewing angle)8-degree viewing angle)
SCI/SCE ModeSCI/SCE Mode
Complies with CIE No.15, GB/TComplies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7
3978 GB 2893 GB/T
18833,ISO7724-1,ASTM E1164,DIN5033 Teil7
Featuredouble apertures, more adaptability; Used for precisesingle apertures, more adaptability; Used for precise color measurement and quality control in plastic electronics, paint and ink, printing and dyeing of textiles and garments, printing, ceramics, and other industries.
color measurement and quality control in plastic electronics,
paint and ink, printing and dyeing of textiles and garments, printing,
ceramics, and other industries
Integrating sphere sizeΦ40mmΦ40mm
Light sourceCombined full-spectrum LED light source, UV light sourceCombined full-spectrum LED light source, UV light source
Spectrophotometric modeflat gratingflat grating
sensorSilicon photodiode array (double row 32 groups)Silicon photodiode array (double row 32 groups)
Wavelength range400~700nm400~700nm
Wavelength interval10nm10nm
Half-bandwidth10nm10nm
Measured reflectance rangeLong: 0~120; reflectivity: 0 ~ 200%Long: 0~120; reflectivity: 0 ~ 200%
Measurement apertureDouble apertures: MAV: Φ8 mm/Φ10 mm; SAV: Φ4 mm/Φ5 mmSingle apertures: Φ8 mm/Φ10 mm
Specular componentSCI/SCESCI/SCE
Color spaceCIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, βxy, DIN Lab9, DINCIE Lab, XYZ, Yxy, LCh, s-RGB, βxy, Munsell (C/2)
Lab99 Munsell(C/2)
Color difference formulaΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*00, DINΔE99ΔE*ab,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99
Other colorimetric indexWI (ASTM E313, CIE/ISO, AATCC, Hunter),WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI(ASTM D1925,ASTM 313),YI(ASTM D1925,ASTM 313),
Metamerism Index MI,Metamerism Index MI,
Staining fastness, color fastness, color intensity,Staining resistance, color fastness, color intensity, opacity, color card lookup
Opacity, color card lookup
Observer angle2°/10°2°/10°
IlluminantD65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF),D65,A,C,D50,F2(CWF), F7(DLF),F10
F8, F9, F10 (TPL5), F11 (TL84), F12 (TL83/U30)(TPL5),F11(TL84),F12 (TL83/U30)
Displayed dataSpectrogram/Values, Samples Chromaticity values, color difference Values/Graph, PASS/FAIL Result, Color Simulation, color compensationSpectrogram/Values, Samples Chromaticity values, color difference values/graph, PASS/FAIL result, color simulation, color compensation
Displayed accuracy0.010.01
Measuring timeAbout 1.5 s (SCI and SCE measurement about 3.2 s)About 1.5 s (SCI and SCE measurement about 3.2 s)
RepeatabilityChromaticity value: MAV/SCI, within ΔE*ab 0.05 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration)Chromaticity value: MAV/SCI, within ΔE*ab 0.06 (when a white calibration plate is measured 30 times at 5-second intervals after white calibration)
Instrument errorMAV/SCI, Within ΔE*ab 0.3MAV/SCI, Within ΔE*ab 0.3
(Average of 12 BCRA Series II color tiles)(Average of 12 BCRA Series II color tiles)
Measurement modeSingle measurement, average Measurement (2-99 times)Single measurement, average measurement (2-99 times)
Location methodCamera location, stabilizer cross positionCamera location, stabilizer cross position
DimensionL*W*H=81X71X214mmL*W*H=81X71X214mm
WeightAbout 460gAbout 460g
BatteryLithium-ion battery, 6000 measurements within 8Lithium-ion battery, 6000 measurements in 8 hours
hours
Illuminant lifespan5 years, more than 3 million times5 years, more than 3 million times measurements
measurements
Monitor3.5-inch color TFT LCD, capacitive touch S3.5-inch color TFT LCD, capacitive touch screen
screen
Data portUSBBluetooth 5.0USB
Data storageStandard 1000 pieces, sample 30000 PC (One1000 standard units, 20000 sample units (one data may include SCI/SCE)
data may include SCI/SCE)
Languagesimplified Chinese, English, traditional Chinesesimplified Chinese, English, traditional Chinese
Operating environment0~40℃, 0~85%RH (non-condensing), Altitude0~40℃, 0~85%RH (non-condensing), Altitude < 2000m
< 2000m
Storage environment -20~50℃, 0~85%HR (non-condensing) -20~50℃, 0~85%HR (non-condensing)
Standard accessoryPower adapter, USB cable, user guide, SQCX software (download from office website), white and black calibration cavity, protective cover, wrist strap, 8 mm flat aperture, 8 mm tip aperture, 4 mm flat aperture, 4 mm tip aperturePower adapter, USB cable, user guide, SQCX software (download from office website), white and black calibration cavity, protective cover, wrist strap, 8 mm flat aperture, 8 mm tip aperture
Optional accessoryUSB micro printer, dust test box, Bluetooth micro printerUSB micro printer, dust test box,
notesTechnical parameters are for reference only, subject to actual product saleTechnical parameters are for reference only, subject to actual product sale
View product

Frequently Asked Questions about the Spectrocolorimeter YR05516

How do I choose the right spectrocolorimeter yr05516 for my laboratory?

Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.

What should I review before requesting a quotation?

Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.

Does Kalstein provide guidance for this type of equipment?

Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.

What maintenance helps extend the equipment lifespan?

Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.

Contact Us

Contact Kalstein