Recirculation Chiller YR02293

The Recirculating Chiller YR02293 - YR02296 is an essential tool designed to provide consistent low temperatures for a wide range of precise scientific processes, including chemical, biological, and physical experiments. Primarily, it serves industries such as medicine, healthcare, food processing, and educational research. With variations in cooling capacities from 1000 to 6000W depending on the model, these chillers are equipped with a renowned brand compressor, ensuring low noise, high reliability, and long-lasting performance. The compact and visually appealing design, combined with an intelligent control system that prevents compressor overload, makes this chiller an efficient addition to any laboratory setting.
This page provides an overview of the Recirculation Chiller YR02293, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories in Germany, with selection criteria adapted to local purchasing, installation and support conditions.
Key factors to consider

Before selecting the Recirculation Chiller YR02293, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
The recirculating chiller is extensively used in laboratory settings for processes that require precise temperature control. Laboratories conducting research in fermentation processes, synthetic chemical reactions, or any experiments demanding stable thermal conditions will find this equipment invaluable. It seamlessly integrates into existing laboratory systems, providing temperature control up to -10°C to 25°C with an exceptional stability of ±2°C.
For the market in Germany, evaluation should consider local context such as industrial labs, Mittelstand pharma, strict DIN/EN standards and match the product to the real workload of the laboratory.
Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
In Germany, budget comparison should include local regulatory requirements, 230V/50Hz power conditions, accessories, logistics and after-sales support.
Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

The recirculating chiller is extensively used in laboratory settings for processes that require precise temperature control. Laboratories conducting research in fermentation processes, synthetic chemical reactions, or any experiments demanding stable thermal conditions will find this equipment invaluable. It seamlessly integrates into existing laboratory systems, providing temperature control up to -10°C to 25°C with an exceptional stability of ±2°C.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

To maximize the performance and longevity of the Recirculating Chiller YR02293 - YR02296, it is recommended to regularly clean the filters and inspect the fluid levels. Ensure that the device is operated within the specified voltage requirements to avoid unnecessary strain on the compressor. Additionally, make use of the liquid level monitor to maintain the correct volume of bath fluid, which aids in consistent temperature management. For any questions or price inquiries, don't hesitate to request a quote or an automatic quotation via the Kalstein Plus platform.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
Support and spare-parts availability oriented to Germany helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Recirculation Chiller YR02293

Recirculation Chiller YR02293
Aplicaciones
El enfriador se usa generalmente para proporcionar condiciones constantes de baja temperatura para inspecciones, experimentos químicos, biológicos y físicos que deben realizarse a baja temperatura, principalmente utilizados para medicina y atención médica, procesos de alimentos, industria química y enseñanza en universidades e institutos de investigación.
Ventajas
- Aplicaciones en química y biología, como fermentador biológico, recipiente químico sintético, etc.
- Equipado con compresor de marca de fama mundial, garantiza bajo nivel de ruido, alta confiabilidad, rendimiento estable y larga vida útil.
- El sistema de circulación completamente cerrado evita que el fluido del baño se evapore o se contamine.
- Los filtros incorporados en la manguera de circulación evitan posibles obstrucciones.
- El refrigerante sin CFC respetuoso con el medio ambiente cumple con las normas internacionales.
- Diseño compacto con apariencia atractiva
- Diseñado con monitor de nivel de líquido, que facilita la verificación del líquido de baño que queda en el tanque.
- La presión del fluido del baño se puede medir con el manómetro que se fija cerca de la salida del fluido.
- Modelos variables para cumplir con los diferentes requisitos del cliente.
- Paneles laterales extraíbles para una limpieza y un mantenimiento rápidos y sencillos.
- El refrigerante ecológico cumple con el estándar internacional de protección ambiental; El sistema de control inteligente evitará que el compresor se sobrecargue, lo que prolongará su vida útil; sistema de circulación cerrado que reduce la evaporación del refrigerante.
Especificaciones Técnicas
| Model | YR02293 (current) | YR02294 | YR02295 | YR02296 |
| Temperature range (°C) | -10~25 | |||
| Temperature stability (°C) | ±2 | |||
| Cooling capacity at 15 degrees (W) | 1000 | 2000 | 3000 | 6000 |
| Flow | 30L / Min Below 1 bar | 40L / min Below 1.5 bars | ||
| Bath volume | 12 | 18 | 25 | 50 |
| Refrigerant | R134A | |||
| Power supply | Single-phase 220V 50HZ | |||
| Dimension LxWxH (mm) | 675×426×695 | 675×456×775 | 740×490×830 | 1020×635×1030 |
Products related to model YR02293
Frequently Asked Questions about the Recirculation Chiller YR02293
What is the primary application of this chiller?
It is used to maintain low temperatures for precise scientific experiments in areas such as chemistry, biology, and physical sciences.
How does the closed circulation system benefit the user?
The closed circulation system prevents bath fluid evaporation and contamination, ensuring stable and accurate temperature conditions.
How do I choose the right recirculation chiller yr02293 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.





