The Electrolyte Analyzer YR06407// YR06417 is a state-of-the-art device engineered to deliver quick and precise results in the measurement of electrolytes in various types of samples, such as serum, plasma, whole blood, and diluted urine. This analyzer features a human-machine interactive menu that allows for dynamic and real-time visualization of sample identifiers. Equipped with automatic liquid level detection, alarms, and real-time diagnostics, it ensures highly reliable performance. The advanced bubble detection and filtration systems prevent clogging, ensuring accurate measurements every time. Additionally, the use of wave theory flushing methods and direct pipe flushing minimizes the risk of clogging and cross-contamination, making it a crucial tool in medical laboratories.
Market Price
The Electrolyte Analyzer price varies based on the model and specific features it offers. Generally, the market price for these devices ranges from $5,000 to $15,000 USD, depending on the additional functionalities and included accessories. It’s essential to evaluate this investment according to the specific requirements of your laboratory or clinic to ensure optimal cost-efficiency and performance.
Frequently Asked Questions
- What types of samples can this device analyze?
- This analyzer is capable of analyzing serum, plasma, whole blood, and diluted urine samples.
- What is the measurement speed of the analyzer?
- The device can perform measurements in less than 30 seconds, ensuring rapid results.
- How is the device calibrated?
- The analyzer features automatic calibration and two-point correction to maintain accuracy.
Advantages and Disadvantages
Advantages:
- High accuracy and speed in measurements.
- Intuitive user interface with real-time data visualization.
- Advanced bubble detection and filtration to prevent clogs.
- Automatic calibration for consistent accuracy and reliability.
- Capacity to store up to 10,000 test results.
Disadvantages:
- Requires a continuous supply of specific reagents.
- Initial investment may be higher compared to less advanced models.
- Regular maintenance is necessary to ensure optimal performance.
Field Use
The Electrolyte Analyzer is indispensable in clinical settings for monitoring and evaluating the electrolyte balance in patients with precision and speed. Its capabilities make it crucial for use in emergency rooms, intensive care units, and clinical laboratories where rapid diagnostic feedback is required. Its versatility in handling various types of samples further extends its applicability across diverse medical scenarios.
Recommendations
To fully leverage the Electrolyte Analyzer, it’s recommended to adhere to regular maintenance schedules and follow the manufacturer’s guidelines for reagent handling and calibration processes. Training staff in the correct use of this device is key to achieving accurate and reliable test results. Maintaining detailed records of tests and calibrations performed will also support ongoing analytical quality. Interested users are encouraged to request a quote or utilize our Kalstein Plus platform for an automatic quotation, which will provide an in-depth cost-benefit analysis to facilitate informed decision-making toward upgrading your laboratory with leading-edge equipment.
Technical Specifications
Model | YR06407 | YR06408 | YR06409 | YR06410 | YR06411 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Analysis Method | ion selective electrode (ISE) | ||||
Measuring speed | <30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Temperature | 5-40°C | ||||
Relative Humidity | <80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na Cl TCO AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO AG | K Na Cl Li |
Model | YR06412 | YR06413 | YR06414 | YR06415 | YR06416 | YR06417 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Analysis Method | ion selective electrode (ISE) | |||||
Measuring speed | <30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Temperature | 5-40°C | |||||
Relative Humidity | <80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO AG | K Na Cl iCa nCa TCa pH Mg Li TCO AG |
K Na Cl iCa nCa TCa pH Mg Li
|
Model | Description |
YRA264 | K Electrode |
YRA265 | K Electrode |
YRA266 | Cl Electrode |
YRA267 | Ca Electrode |
YRA268 | pH Electrode |
YRA269 | Li Electrode |
YRA270 | Mg Electrode |
YRA271 | Ref. Electrode |
YRA272 | Reagent Pack Calibration A 430ml; Calibration B 110ml; ( For Model H900 only) |
YRA273 | Reference Electrode Internal Solution – 10ml |
YRA274 | Electrode Internal
Solution – 3ml |
YRA275 | Activating Solution – 110ml |
YRA276 | QC Solution Level 2
(Water-based) – 110ml |
YRA277 | Cleaning Solution – 110ml |
YRA278 | Electrode Wash Solution (Protein Enzyme) -125mg (25mg/bottle x5) |
YRA278-1 | Electrode Wash Solution (Diluent) – 5ml ( 1 bottle) |